CEN/TR 1046:2013

Thermoplastics piping and ducting systems - Systems outside building structures for the conveyance of water or sewage - Practices for underground installation

WITHDRAWN

About this standard

Languages
English and French
Type
NBN
Standards committee
CEN/TC 155
Status
WITHDRAWN
Publication date
01 December 2013
Replaces
CEN/TS 14758-3:2006, NBN CEN/TS 1852-3/A1:2005, NBN ENV 1401-3:2001, CEN/TS 1852-3:2003, NBN ENV 1046:2001
Replaced by
CEN/TS 1046:2021
ICS Code
23.040.05 (Pipelines and its parts for external sewage systems)
23.040.20 (Plastics pipes)
23.040.45 (Plastics fittings)
93.030 (External sewage systems)
Withdrawn Date
07 March 2023

About this training

Summary

This Technical Report is applicable to the installation of thermoplastics piping systems to be used for the conveyance of water or sewage under gravity and pressure conditions underground. It is intended to be used for pipes of nominal size up to and including DN 1600.
Wherever the term " pipe" is used in this Technical Report, it also serves to cover any " fittings" , " ancillary" products and " components" if not otherwise specified.
NOTE 1 This document does not apply to pipelines for gas supply (see EN 12007-2, Gas supply systems pipelines for maximum operating pressure up to and including 16 bars - Part 2: Specific functional recommendations for PE- and MOP up to and including 10 bars).
NOTE 2 It is assumed that additional recommendations and/ or requirements are detailed in the individual materials voluntary product standards. Instances where this is expected to apply include those indicated in this Technical Report as follows:
a) any special transportation requirements (see 5.2)
b) maximum storage height (see 5.2 and 5.4)
c) maximum storage period in direct sunlight (see 5.4)
d) any climatic conditions requiring special storage (see 5.4)
e) limiting initial and/ or long-term deflections (see 6.1.1 and 6.1.2)
f) information on mole ploughing and boring (see and 6.2), if applicable
g) selection of appropriate jointing system (see Clause 7)
h) recommended radii of curvature for cold bending (see 8.1)
i) permitted rates of loss of water under test (see 9.2.1)
j) if applicable the relationship between SDR and stiffness.
Requirements and instructions concerning commissioning of systems can be found in EN 805 and EN 1610 and the relevant national and/ or local regulations.