NBN EN 15698-1:2009

District heating pipes - Preinsulated bonded twin pipe systems for directly buried hot water networks - Part 1: Twin pipe assembly of steel service pipe, polyurethane thermal insulation and outer casing of polyethylene

WITHDRAWN

About this standard

Languages
German, English and French
Type
NBN
Standards committee
CEN/TC 107
Status
WITHDRAWN
Publication date
02 April 2009
ICS Code
23.040.07 (Pipelines and its parts for district heat)
23.040.10 (Iron and steel pipes)
Withdrawn Date
28 November 2019

About this training

Summary

This European Standard for District Heating Twin Pipes, specifies requirements and test methods for straight lengths of prefabricated thermally insulated pipe-in-pipe assemblies for directly buried hot water networks, comprising two steel service pipes from DN 15 to DN 250, rigid polyurethane foam insulation and one cylindrical outer casing of polyethylene. The pipe assembly may also include the following additional elements: Measuring wires, spacers and diffusion barriers.
This standard applies only to insulated twin pipe assemblies, for continuous operation with hot water at various temperatures up to 120 °C and occasionally with a peak temperature up to 140 °C.