NBN ISO 20890-5:2021

Guidelines for in-service inspections for primary coolant circuit components of light water reactors — Part 5: Eddy current testing of steam generator heating tubes (ISO 20890-5:2020)

ACTIVE

About this standard

Languages
English
Type
NBN
Standards committee
NBN/I08506
Status
ACTIVE
Publication date
08 May 2021
ICS Code
27.120.10 (Reactor engineering)
Withdrawn Date

About this training

Summary

This document gives guidelines for pre-service inspection (PSI) and in-service inspections (ISI) by eddy
current tests on non-ferromagnetic steam generator heating tubes of light water reactors, whereby the
test is carried out using mechanised test equipment outwards from the tube inner side.
An in-service eddy current test of steam generator heating tube plugs as a component of the primary
circuit is not an object of this document. Owing to the different embodiments of steam generator
heating tube plugs, the use of specially adapted test systems to be qualified is necessary.
Test systems for the localisation of inhomogeneities (surface) and requirements for test personnel, test
devices, the preparation of test and device systems, the implementation of the testing as well as the
recording are defined.
NOTE Data concerning the test section, test extent, inspection period, inspection interval and evaluation of
indications is defined in the nuclear safety standards.
It is recommended that the technical specifications are based on experience on U-tube bends with even
bend radius (similar to the S/ KWU design). To test other kind of tube bends (e.g. U-tube bends with two
90° bends) further qualifications will be provided.