NBN EN ISO 13163:2019

Water quality - Lead-210 - Test method using liquid scintillation counting (ISO 13163:2013)

WITHDRAWN

About this standard

Languages
German, English and French
Type
NBN
Standards committee
CEN/TC 230
Status
WITHDRAWN
Publication date
26 June 2019
Replaced by
NBN EN ISO 13163:2022
ICS Code
13.060.60 (Examination of physical properties of water)
17.240 (Radiation measurements)
Withdrawn Date
05 March 2022

About this training

Summary

ISO 13163 specifies the determination of lead-210 (210Pb) activity concentration in samples of all types of water using liquid scintillation counting (LSC). For raw and drinking water, the sample should be degassed in order to minimize the ingrowth of 210Pb from radon-222 (222Rn).
Using currently available liquid scintillation counters, this test method can measure the 210Pb activity concentrations in the range of less than 20 mBq⋅l-1 to 50 mBq⋅l-1. These values can be achieved with a counting time between 180 min and 720 min for a sample volume from 0,5 l to 1,5 l.
Higher 210Pb activity concentrations can be measured by either diluting the sample or using smaller sample aliquots or both.
It is the laboratory' s responsibility to ensure the suitability of this test method for the water samples tested.